  rev: 1-b-021318 based on manual rev 0 motor and pump protection - single and 3-phase ?2018 littelfuse protection relays & controls www.littelfuse.com/MP8000 MP8000 series description the MP8000 are advanced motor protection electronic overload relays, fully programmable via bluetooth ? using an iphone ? or android? smartphone or tablet with the littelfuse app. it is easy to use and arc-flash safety is increased because the app allows settings to be modified and real-time operational information viewed. viewing operational information and faults on the app does not require the user to open the control panel. the MP8000 protects any motor drawing 0.5-1,000 full load amps (external cts are required above 100 amps). it is designed for single or 3-phase systems with operating voltages of 90-690 vac (use of external potential transformers can extend upper voltage range above 690 vac). common applications include conveyor systems, hvac equipment, saws and grinders, fan motors, and almost any pumping application. protection is unsurpassed by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload in one package. for standalone applications, the bluetooth ? interface can be used when paired with a smartphone or tablet. the units also feature an ethernet communications port that can be used to form an ethernet modbus tcp/ip network or ethernet/ip. units can be remotely monitored and controlled from a pc, or scada system, and data logging through a pc with the optional solutions software or other software program using the MP8000 memory map. this capability allows for a simple cost-effective way to further enhance arc-flash safety. features & benefts features benefits bluetooth ? interface visual indication for programming, viewing real-time voltage or current, and last fault information (date and time stamped) programmable voltage and current settings allows usage on wide range of systems 3 selectable restart options choose from automatic, semi-automatic, or manual to best meet individual application needs 4 programmable delay timers program separate delay times for power up, rapid cycle protection, motor cool down, and underload restarting flexible reset reset can be done through pushbutton on panel, remotely via the network network communications capability compatible with ethernet modbus tcp/ip and ethernet/ip bluetooth ? overload relay wiring diagram no (15) c (13) . i. 2 i. 1 MP8000 ptc (optional) rese t from a2 pe c (95) l1 l3 l2 a2/l z1 z2 t1 t2 phase a phase b phase c aux voltage supply zero-sequence current transformer (optional) a b c no (96) nc (14) c pilot star t c stop aut o hand off from a1 m a1/n 85 ? 264 va c 90 - 690 va c 0.5 - 100a (100a+ using ex t ernal ct s) ordering information model line voltage motor full amp range description MP8000 90-690vac (use of external potential transformers can extend upper voltage range above 690vac) 0.5-1,000a+ (external cts required above 100a) provides remote wired communication via ethernet modbus tcp/ip or ethernet/ip typical wiring diagram for 3-phase patent pending protection relays and controls
rev: 1-b-021318 based on manual rev 0 motor and pump protection - single and 3-phase ?2018 littelfuse protection relays & controls www.littelfuse.com/MP8000 MP8000 series advanced features overload/overpower (49) underload/underpower (37p) overcurrent (51)/jam undercurrent (37) current unbalance/phase loss (46) phase reversal (47) overvoltage (59) undervoltage (27) voltage unbalance (47) rapid cycling/jog contactor failure zero-sequence ground fault (50ns) ptc motor overtemperature (49) real time confguration fault specifcations functional characteristics frequency 50/60hz tc- overcurrent trip class trip class 02-60 or linear output characteristics output contact rating control relay spst - form a auxiliary relay spdt - form c pilot duty rating b300 general purpose 5a @ 240vac general characteristics ambient temperature range operating -40 to 70c (-40 to 158f) storage -40 to 85c (-40 to 185f) accuracy voltage 1% of reading 0.5 v current 2% (2 to 100 amps direct) timing +/-0.5% of setting +/- 1second gf current 5% repeatability voltage 0.5% current 1% (2 to 100 amps direct) power consumption <5 w pollution degree 3 (conformal coating standard) class of protection ip20 relative humidity 10-95%, non-condensing per iec 68-2-3 terminal torque (depluggable terminal blocks) 5.5 in.-lbs. terminal torque (earth ground) 7.9 in.-lbs. standards passed electrostatic discharge (esd) iec 61000-4-2, level 3, 6kv contact, 8kv air radio frequency immunity (rfi), conducted iec 61000-4-6, level 3 10v/m radio frequency immunity (rfi), radiated iec 61000-4-3, level 3 10v/m fast transient burst iec 61000-4-4, level 3, 3.5kv input power surge iec 61000-4-5, level 3, 2kv line-to-line; level 4, 4kv line-to-ground fcc rating part 15.107 for emissions, part 15.247 for intentional radiators short circuit withstand rating 100ka symmetrical at 690vac hi-potential test meets ul508 (2 x rated v +1000v for 1 minute) safety marks culus ul60947, ul1053, c22.2 (file #e68520) ce iec 60947 edition 5.2, iec 60947-8 maximum conductor size (with insulation) 0.63 dimensions h 74.42 mm (2.93); w 103.63 mm (4.08); d 121.67 mm (4.79) weight 0.85 lbs (13.6 oz, 385.6 g) mounting method surface mount (4 - #8 screws) or din-rail mount MP8000 littelfuse app icon disclaimer notice C information furnished is believed to be accurate and reliable. however, users should independently evaluate the suitability of and test each product selected for their own applications. littelfuse products are not designed for, and may not be used in, all applications. read complete disclaimer notice at www.littelfuse.com/product-disclaimer. protection relays and controls


▲Up To Search▲   

 
Price & Availability of MP8000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X